Port Reference

Detailed information about each port on the WOLF ONE node.

Port Layout​

The WOLF ONE node has ports on the front and back panels.

Front Panel​

PortQuantityConnectorColor Code
Camera Ports62.5mm TRSCamera trigger output (RGB LED)

Back Panel​

PortQuantityConnectorPurpose
TRS Input13.5mm TRSExternal trigger input (pink color)
Mono Ports23.5mm TSGeneral Purpose / Strobe output (RGB LED)
HowlNET OUT1RJ45Send to next node
HowlNET IN1RJ45Receive from previous node
DC Power15.5x2.5mm barrel24V DC input
USB Host1Type-A
USB Power/Data1Type-CComputer connection

Camera Ports (1-6)​

Compatible with most cameras that has an external remote shutter release port.

  • Connector: 2.5mm TRS (Tip-Ring-Sleeve)
  • Port Color: Black

Pin Assignment​

PinSignalFunction
TipFocusShutter release / Trigger
RingShutterAuto-focus / Wake
SleeveGroundCommon ground

Electrical Specifications​

ParameterValue
Output TypeOpen-drain (sinking / low-side)
Max pull-up voltage+24 V (relative to product GND)
Sink current (recommended)≤ 10 mA continuous
Sink current (absolute max)50 mA
Usage requirementMust be used with an external pull-up resistor or other current-limiting device
Protection:No reverse-polarity protection. Miswiring may damage the device.

Arc Eye Camera Sync Cables:


Mono Ports (1-2)​

Compatible with most Strobe/flash triggers and Wireless transmitters

  • Connector: 3.5mm TS (Tip-Sleeve, mono)
  • Port Color: Black

Pin Assignment​

PinSignalFunction
TipTriggertrigger signal
SleeveGroundCommon ground

Electrical Specifications​

ParameterValue
Output TypeOpen-drain (sinking / low-side)
Max pull-up voltage+24 V (relative to product GND)
Sink current (recommended)≤ 10 mA continuous
Sink current (absolute max)50 mA
Usage requirementMust be used with an external pull-up resistor or other current-limiting device
Protection:No reverse-polarity protection. Miswiring may damage the device.

Typical Uses​

  • Strobe/flash triggers
  • Wireless transmitter triggers (PocketWizard, etc.)
  • External device triggers
  • Relay control

:::warning High Voltage Flash Some vintage flash units have trigger voltages exceeding 200V. These require an isolation adapter or modern wireless trigger to protect the WOLF ONE outputs. :::

Tested Trigger Systems:

Brand/ModelTypeCompatibility
PocketWizard PlusRadio✓ Supported
PocketWizard FlexTT5Radio✓ Supported
Direct PC SyncWired✓ Supported

TRS Input Port​

Compatible with most momentary buttons and switching outputs.

  • Connector: 3.5mm TRS Stereo
  • Port Color: Pink

Pin Assignment​

PinSignalFunction
TipTriggerTrigger input (active-low)
RingWakeWake input (active-low)
SleeveGroundCommon ground

Input LED State​

LED ColorState
GreenConnected
OffDisconnected

Electrical Specifications — TRS Input​

ParameterValue
Interface TypeDigital input, contact closure to ground (active-low)
Internal pull-up voltage3.3 V (internal)
Internal pull-upsYes (Tip and Ring)
Idle stateTip and Ring = HIGH
Triggered stateTip or Ring shorted to Sleeve (GND) = LOW
Input driveDry-contact only (do not drive with external voltage)
ProtectionNo overvoltage or reverse-polarity protection. Miswiring may damage the device.

Typical Uses​

  • Arc Eye Handheld Controller
  • Foot pedals
  • Wired remote triggers
  • Custom trigger circuits

⚠️ DO NOT CONNECT​

  • External voltage sources
  • Audio or headphone outputs
  • TRRS plugs or phone headsets
  • Powered logic signals

This port accepts dry-contact closures only. This is a control input, not an audio jack.

Button Behavior​

  • On daisy-chained systems, buttons on any node trigger all nodes

HowlNET Ports (IN/OUT)​

Connector: RJ45

Purpose​

Daisy-chain multiple WOLF ONE nodes into a synchronized network.

Connection Rules​

  • Connect HowlNET OUT of one WOLF to HowlNET IN of the next WOLF
  • First node in the chain is the Director
  • Subsequent nodes nodes are Listeners
  • The Director node connects to USB for computer control

Specifications​

ParameterValue
ProtocolHowlNET over RJ45
Maximum Cable Length100m (328 ft) total length
Maximum Nodes32

Cable Requirements​

Recommended Cable:

Cable TypeRequired Spec
HowlNet Bus CableShielded 24AWG
Cat5e / Cat6Shielded 24AWG
warning

Do NOT use crossover cables. Do not connect HowlNET ports to standard Ethernet switches or routers. HowlNET uses a proprietary protocol.


DC Power Port​

Connector: 5.5mm x 2.5mm barrel jack

ParameterValue
Voltage24V DC
Current2.5A maximum
PolarityCenter positive

Power Distribution​

When nodes are daisy-chained via HowlNET, power is distributed through the network:

  • Connect 24V adapter to the first node only
  • Power flows through HowlNET cables to all nodes
  • Each node consumes 1W idle, 1.6W peak, 2W maximum

USB Type-C Port​

Connector: USB Type-C

Functions​

  1. Power Input: 5V USB power for single-node operation
  2. Configuration: USB communication with Leash app
  3. Firmware Updates: Flash new firmware via Leash app

Box Buttons​

ButtonFunction
WakeActivate camera auto-focus
TriggerActivate Effect (trigger cameras)

Button Behavior​

  • On daisy-chained systems, buttons on any node trigger all nodes