Skip to main content
Version: 1.12.04

Safety Information

Read all safety instructions before operating your WOLF ONE system.

Electrical Safety

Power Requirements

SpecificationValue
BUS Barrel Port Voltage12-24V DC
BUS Maximum Current2A Fused
USB Power5V via Type-C
Node Power Consumption (Max)2W

Warnings

Electrical Hazards
  • Do not exceed 24V DC input - Higher voltages may damage the unit or cause fire
  • Use only the supplied power adapter or a compatible 24V DC, 2.5A power source
  • Do not operate with damaged cables - Inspect all cables before use
  • Keep away from water and moisture - The unit is not waterproof
  • Do not open the enclosure - Opening enclosure may void warranty

Grounding

  • When using multiple power sources for cameras, strobes, and nodes, ground loops may occur
  • If you experience erratic behavior or calibration issues, try:
    • Powering all equipment from the same electrical circuit
    • Using wireless trigger adapters to isolate signals
    • Reducing the number of interconnected cables

Electrostatic Discharge (ESD)

Before handling the node:

  • Touch a grounded metal object to discharge static
  • Avoid working on carpet or synthetic materials
  • Handle by the enclosure edges, not the ports

Operating Environment

ConditionSpecification
Operating Temperature0°C to 40°C (32°F to 104°F)
Operating Humidity10% to 80% relative humidity, non-condensing
Intended EnvironmentIndoor use only
Ingress ProtectionNot rated for water or dust ingress
Environmental Requirements
  • Indoor use only - Designed for controlled studio and production environments
  • Not for outdoor use - Not intended for outdoor, wet, or high-condensation locations
  • Avoid direct sunlight for extended periods or your enclosure may become discolored

Cable Safety

Maximum Cable Lengths

Cable TypeMaximum LengthNotes
HowlNET (RJ45)100m (328 ft)
USB Type-C3m (10 ft)USB 2.0
Camera cables10m (32 ft)Varies by camera

Cable Handling

  • Do not bend cables at sharp angles
  • Do not run cables under heavy objects
  • Strain relief: Secure cables to prevent connector stress
  • Disconnect by gripping the connector, not the cable

Firmware Updates

Firmware Flashing
  • Disconnect 24V bus power before flashing
  • Connect only USB Type-C to the node being flashed
  • Do not disconnect during firmware update
  • A failed update may require factory service

Multi-Node Systems

When daisy-chaining nodes:

  • Use a single 24V power source for the entire chain
  • Connect HowlNET OUT → HowlNET IN between nodes
  • Ensure adequate power capacity for all nodes

Camera and Strobe Safety

Camera Port Ratings

Trigger Outputs (Camera/Mono Ports):

  • Output type: Optically isolated open collector
  • Maximum switching current: 50mA
  • Maximum switching voltage: 24V
  • Maximum power dissipation: 100mW
  • Maximum reverse voltage: 5V
  • No voltage generated by output (requires external pull-up)

Trigger Inputs (Input Port):

  • Input voltage: 3.3V logic (pull-up)
Input Port Warning

DO NOT apply external voltage to input ports

  • Input ports are for signal sensing only
  • Applying external voltage may damage the node

Strobe and Flash Compatibility

  • Follow your camera manufacturer's safety guidelines
  • Some vintage flash units have high trigger voltages (>12V) - verify compatibility before connecting
  • Allow strobes to fully recycle before triggering

Regulatory Information

Patents

U.S. Patent Numbers: 11669483, 11210258

Disposal

Dispose of electronic equipment according to local regulations. Do not dispose of in household waste.

Emergency Procedures

If the unit emits smoke, unusual odor, or excessive heat:

  1. Immediately disconnect all power sources
  2. Do not attempt to operate the unit
  3. Contact Arc Eye support

If liquid enters the unit:

  1. Disconnect power immediately
  2. Do not attempt to power on
  3. Allow to dry completely before inspection
  4. Contact Arc Eye support before use

Next Steps

Now that you understand safety requirements: